CONSTRUCTION
AND SPECIFICATION |
|
Sizes |
DN15-DN80
(˝" - 3") |
Standard Flow
Ranges
Air (ATP)
Water |
1.2 – 700 m3/hr
40 l/hr – 40 m3/hr |
Instrument
Types
Direct Reading
Alarm
Transmitter |
100mm Scale
Single or Dual NAMUR Type
2-wire 4 to 20mA |
Approvals
Alarm
Transmitter |
EEx ia IIC T6
EEx ia IIC T6 or EEx nA II T6 |
|
Accuracy |
± 2% FSD |
|
Repeatability |
0.5% of Flow |
|
Materials |
316 SS
standard |
Connections
Flanged
Screwed |
DIN PN16 or ANSI 150 (or to customer’s request)
BSP female |
|
Installation
length |
250mm |
|
Protection |
IP65 |
|
Fluid Pressure
(max.) |
100bar (or
flange rating) |
|
Temperature
Range |
-30° to +65°C
Ambient
-40° to +120°C Fluid * |
|
*Higher
temperature versions available, please enquire |
FEATURES AND BENEFITS
| Clear
100mm Scale |
 |
Easily
Read on Plants |
| Modular
Output Devices |
 |
Simple In
situ Upgrading |
|
Independent 4 to 20mA Output |
 |
Verifiable Performance |
| Liquid or
Gas Metering |
 |
Suitable
for Many Plant Applications |
| Simple
Construction |
 |
Rugged
and Easily Installed |
| Stable
Zero Point |
 |
Unaffected by Installation |
| Low
Hysteresis |
 |
Repeatable Performance |
HOW FLOTRAK WORKS
Fluid, passing
through an orifice within the tube, causes a profiled
float to assume a position where the forces created by
flow are balanced by the weight of the float. A magnet
in the float is sensed by the FloTrak system, providing
a direct reading flow rate scale, optional alarms or an
independent 4 to 20mA transmitter.
INSTRUMENT
OPTIONS
The FloTrak meter
is installed in a vertical line with flow upwards and is
normally supported by the surrounding pipework. Several
styles of instrument are available:
Flow Alarm
Unit
The Direct Reading Indicator with one or two fully
adjustable set-point trips, for connection via an
interface unit.
Transmitter
4 to 20mA loop output proportional to percentage of
reading. Available with the Direct Reading Indicator. |