The NGS Dual Magnet Float Level Switch operates as the level rises and falls the inclination of the float is changed causing a permanent magnet in the float to be deflected which in turn repels a rotatable opposing magnet. This forced snap-action-contact effect operates a microswitch with a plunger. Even very small changes in level can be detected in this way. For all technical information refer to NGS data sheet below
For liquids Contact: 1 micro switch
Connection:square flange, G 2, 2″ NPT DIN-flange:
DN80, DN100 Material: st. st. 1.4571
Max. pressure: 25 bar Max.temperature:250°C
Liquid density: ab 0,7 g/ml
Certificates: ATEX, Germanischer Lloyd